UV Monitor is fully programmable with an LED display. All parameters can be changed using the built-in programming menu. The UV Monitor is factory set and as such is suited to most applications. Measurements taken are of UV intensity at the reactor face and the water temperature. The system has a light display that indicates Normal, Warning and Alarm parameters with detailed information shown in the digital display. The system operates a solenoid dump valve fitted to the AOP system to insure reactor water temperatures are kept below 50ºC and has an output to enable the operational status to be seen remotely.
UV Lamp Controller is fully programmable with a light display that indicates Normal, Warning and Alarm parameters. It is designed to operate a single lamp and comes factory set and as such is suited to most applications. It has an output to enable the operational status to seen remotely.
The UV Lamp Controller has a number of innovative features that include a programmable lamp pre-heating profile that insures initial lamp current is carefully controlled to give a ‘mild lamp start-up’. To further maximise lamp life the controller reacts to the lamp filament’s resistance to give a soft heating function.
The dimensions of the control cabinets are set out below
AOP1 | AOP5 | AOP10 | AOP20 | AOP50 | AOP100 | AOP400 | |
---|---|---|---|---|---|---|---|
Height
|
300mm
|
300mm
|
300mm
|
800mm
|
800mm
|
1200mm
|
1900mm
|
Width
|
400mm
|
400mm
|
500mm
|
600mm
|
600mm
|
600mm
|
1300mm
|
Depth
|
210mm
|
210mm
|
210mm
|
300mm
|
300mm
|
600mm
|
600mm
|